Boonton 4500B RF Peak Power Analyzer
Remote Operation
5-100
Table 5-1. SCPI COMMAND SUMMARY (continued)
DISPlay:PARAmeter:MIDdle:LEFT Assign numbered parameter to middle left field. (ex: <arg> = PWIDTH)
DISPlay:PARAmeter:MIDdle:MIDdle Assign numbered parameter to middle middle field. (ex: <arg> = PWIDTH)
DISPlay:PARAmeter:MIDdle:RIGHt Assign numbered parameter to middle right field. (ex: <arg> = PWIDTH)
DISPlay:PARAmeter:MODE Set parameter mode to status or measure. <arg> = MEAS, STAT
DISPlay:PARAmeter:TOP:LEFT Assign numbered parameter to top left field. (ex: <arg> = PWIDTH)
DISPlay:PARAmeter:TOP:MIDdle Assign numbered parameter to top middle field. (ex: <arg> = PWIDTH)
DISPlay:PARAmeter:TOP:RIGHt Assign numbered parameter to top right field. (ex: <arg> = PWIDTH)
DISPlay:PCTOFST Display horizontal offset in linear presentation. <arg> = 0.0 to 99.0
DISPlay:PCTSCALE Display horizontal scale in linear presentation. <arg> = 10, 5, 2, 1, 0.5, 0.2, 0.1
DISPlay:PERSistence Set/get display persistence. <arg> = ON, OFF
DISPlay:PLABel:MODE Turn on/off four plot labels on graph display. <arg> = OFF, ON
DISPlay:PLABel:TEXTA Enter string into first plot label field. <arg> = string of up to 19 characters
DISPlay:PLABel:TEXTB Enter string into second plot label field. <arg> = string of up to 19 characters.
DISPlay:PLABel:TEXTC Enter string into third plot label field. <arg> = string of up to 19 characters
DISPlay:PLABel:TEXTD Enter string into fourth plot label field. <arg> = string of up to 19
characters
DISPlay:PULSe:TIMEBASE Set/return horizontal timebase. (Ex: <arg> = 0.05 sets timebase to 50 ms)
DISPlay:SCREensaver:BRIGhtness Set/return display brightness in screensaver mode. <arg> = 10 to 50
DISPlay:SCREensaver:STATe Set/return state of screensaver mode. <arg> = ON, OFF
DISPlay:SCREensaver:TIMe Set/return time until display dims. <arg> = 1 through 240
DISPlay:SKEW[1|2|3|4|6|7]:REFerence Set/return the skew reference channel. <arg> = CH1, CH2, TRIG1,
TRIG2, MEM1, MEM2
DISPlay:STATistical:MODE Set/return statistical mode. <arg> = CCDF, CDF, or PDF
DISPlay:STATistical:PRESentation Set/return presentation of horizontal grid. <arg> = LIN, LOG
DISPlay:STATistical:PREView Set/return display in split screen mode. <arg> = ON or OFF