Boonton 4540 Series RF Power Meter
Operation
Table 4-1 Field Parameter Selection List
Automatic Pulse Time Measurement: Pulse width (on time)
Automatic Pulse Time Measurement: Rising edge transition time
Automatic Pulse Time Measurement: Falling edge transition time
Automatic Pulse Time Measurement: Waveform pulse repetition period
Automatic Pulse Time Measurement: Waveform pulse repetition interval
Automatic Pulse Time Measurement: Waveform duty cycle
Automatic Pulse Time Measurement: Off time between pulses
Automatic Pulse Power Measurement: Instantaneous Peak Power
Automatic Pulse Power Measurement: Pulse average ―on‖ power
Automatic Pulse Power Measurement: Leading edge overshoot
Automatic Pulse Power Measurement: Power over one full cycle of waveform
Automatic Pulse Power Measurement: IEEE Top Power of pulse
Automatic Pulse Power Measurement: IEEE Top Power of pulse
Automatic Edge Delay Measurement: channel-to-channel ―first edge‖ time skew
Automatic Edge Delay Measurement: ―first edge‖ time offset from start of trace
Selected Channel’s RF Frequency setting
Selected Channel’s currently applied Frequency Calfactor correction
Selected Channel’s video bandwidth setting for peak sensors
Selected Channel’s video averaging setting for Pulse Mode
Trigger Source, Polarity and Level settings
Trigger Delay setting for Pulse Mode
Selected Channel’s vertical scale setting for trace display
Selected Channel’s vertical center setting for trace display
Selected Channel’s gain offset setting in dB
Marker Measurement: Average power over marker interval
Marker Measurement: Maximum instantaneous power over marker interval
Marker Measurement: Minimum instantaneous power over marker interval
Marker Measurement: Maximum filtered power over marker interval
Marker Measurement: Minimum filtered power over marker interval
Marker Measurement: Peak-to-Average power ratio over marker interval
Marker Measurement: Average power at marker 1
Marker Measurement: Average power at marker 2
Marker Measurement: Marker 1 to Marker 2 delta
Marker Measurement: Highest value of average-between-markers
Marker Measurement: Lowest value of average-between-markers
Marker Measurement: Minimum instantaneous power at marker 1
Marker Measurement: Maximum instantaneous power at marker 1
Marker Measurement: Minimum instantaneous power at marker 2
Marker Measurement: Maximum instantaneous power at marker 2
Marker Measurement: Marker 1 to Marker 2 ratio
Marker Measurement: Marker 2 to Marker 1 ratio
Marker Measurement: Marker 2 to Marker 1 delta
Selected Sensor’s internal temperature (peak sensors)